Technical data
Housing
Protection rating (EN60529)
  • IP66
Case material
  • Type RA80
  • Explosion-proof and flame-proof
  • Epoxy painted, Aluminium
  • Captive stainless steel screws
Mounting
  • Wall mounting, 3 back lugs
Scale
  • Internal, accuracy on reading ± 5 % FS
Process
Process connection
  • G1/2"
  • 1/2" NPT
  • 1/4" NPT female
Temperature
Ambient temperature
  • -20°C ... +55°C (T6)
Storage temperature
  • -40°C ... +70°C
Media temperature
  • -50°C ... +200°C
Wetted parts
Bellow
  • Stainless steel 1.4404 / AISI 316L
  • Stainless steel 1.4432 / AISI 316L
Sensing / Input
Min. measuring range
  • 0.05 ... 0.5 bar
Max. measuring range
  • 2.5 ... 30 bar
Performance
Repeatability
  • ± 1 % FS
Adjustment
  • 2 external adjustment screws on top of the case for set point and deadband
  • When set point adjustment is required it is necessary to know the static pressure, as it has an influence on the set point.
Electrical data
Ground connection
  • Via internal terminal block
Electrical connection
  • Via internal terminal block with metallic cable gland for Ø 7 to 12 mm
Approval / Conformities
ATEX/IECEx Certificate
  • LCIE 03 ATEX 6231X (Type RA80)
  • IECEx LCIE 15.0061X
ATEX/IECEx
  • Ex II 2 GD
  • Further information can be found in the ATEX approval
CE conformity
  • ATEX directive 2014/34/UE

Downloads
Data sheet
Operating Manual
Certificates / approvals
Declaration of Conformity

Drawings
Drawings

Pressure range codes: 211 - 221

(png | 88 KB)

Pressure range codes: 214 - 224 - 234 - 235 - 245 - 246 - 256 - 257 - 258

(png | 77 KB)

To the top