Technical data
Housing
Nominal size
  • 100 mm
Case material
  • Stainless steel 1.4301 / AISI 304
  • Stainless steel 1.4404 / AISI 316L, optional
Bezel ring material
  • Stainless steel 1.4301 / AISI 304
  • Stainless steel 1.4404 / AISI 316L, optional
Window material
  • Laminated safety glass
Window gasket
  • Elastomer
Protection rating (EN 60529)
  • IP65
Dial
  • White, aluminium
Pointer
  • Black, aluminium
Movement material
  • Stainless steel
Temperature
Ambient temperature
  • -20°C ... +70°C
Storage temperature
  • -40°C ... +70°C
Media temperature
  • -40°C ... +200°C (not filled)
Wetted parts
Process connection material
  • Stainless steel 1.4404 / AISI 316L
Bourdon tube
  • Stainless steel 1.4404 / AISI 316L
Performance
Min. measuring range
  • 0 ... 1 bar
Max. measuring range
  • 0 ... 1600 bar
Type of pressure
  • Gauge
  • Vacuum
  • Compound
Pressure limitation (ranges ≤ 600 bar)
  • Steady: 100 % of full scale value
  • Fluctuating: 90 % of full scale value
  • Short time: 130 % of full scale value
Pressure limitation (ranges > 600 bar)
  • Steady: 75 % of full scale value
  • Fluctuating: 65 % of full scale value
  • Short time: 100 % of full scale value
Thermal drift (reference: +20 °C)
  • ± 0.4 % FS/10K
Electrical data
Number of setpoints
  • 1 or 2
Electrical connection
  • Via internal terminal block
  • M20 x 1.5
Type of contact
  • Inductive contacts with sensor according to EN 60947-5-6 (NAMUR)
  • Sensor type SJ2-N
Min. pressure for 1 contact
  • 1 bar
Min. pressure for 2 contacts
  • 1.6 bar
Weight
Gauge
  • 750 g unfilled
  • 1300 g filled
Approval / Conformities
ATEX
  • Ex II 2 G
  • Further information can be found in the ATEX approval

Downloads
Operating Manual
Certificates / approvals
Declaration of Conformity

Drawings