Technical data
Housing
Nominal size
  • 160 mm
Case material
  • Stainless steel 1.4301 / AISI 304
Bezel ring material
  • Stainless steel 1.4301 / AISI 304
Window material
  • Instrument glass
Window gasket
  • Elastomer
Protection rating (EN 60529)
  • IP65
Dial
  • White, Aluminium
Pointer
  • Black, Aluminium, with edgewise tip
Movement material
  • Stainless steel
Temperature
Ambient temperature
  • -20°C ... +70°C
Storage temperature
  • -40°C ... +40°C ,Code 40
Media temperature
  • -40°C ... +200°C
Wetted parts
Process connection material
  • Stainless steel 1.4404 / AISI 316L
Bourdon tube
  • Stainless steel 1.4404 / AISI 316L
Performance
Accuracy
  • Class 0.6
Min. measuring range
  • -0.6 ... 0 bar
Max. measuring range
  • 0 ... 1000 bar
Pressure limitation
  • Steady: 75 % of full scale value
  • Fluctuating: 60 % of full scale value
  • Short time: 100 % of full scale value
Thermal drift (reference: +20 °C)
  • ± 0.4 % FS/10K
Calibration
  • P ≤ 60 bar with air
  • P > 60 bar with fluid
Weight
Gauge
  • 980 g