Technical data
Housing
Nominal size
  • 100 mm
Case material
  • Stainless steel 1.4301 / AISI 304
Bezel ring material
  • Stainless steel 1.4301 / AISI 304
Window material
  • Instrument glass
Window gasket
  • Elastomer
Protection rating (EN 60529)
  • IP65
Dial
  • White, Aluminium
Pointer
  • Black, Aluminium
Movement material
  • Brass
Temperature
Ambient temperature
  • -20°C ... +70°C
Storage temperature
  • -40°C ... +70°C
Media temperature
  • -20°C ... +70°C
Wetted parts
Process connection material
  • Brass
Bourdon tube
  • Bronze
Performance
Accuracy according to EN 837-1
  • Class 1
Min. measuring range
  • 0 ... 0.6 bar
Max. measuring range
  • 0 ... 60 bar
Type of pressure
  • Gauge
  • Vacuum
  • Compound
Pressure limitation
  • Steady: 100 % of full scale value
  • Fluctuating: 90 % of full scale value
  • Short time: 130 % of full scale value
Thermal drift (reference: +20 °C)
  • ± 0.4 % FS/10K
Weight
Gauge
  • 510 g unfilled
  • 810 g filled

Downloads
Data sheet

To the top