Technical data
Housing
Protection rating (EN60529)
  • IP66
Cover
  • Blue painted, zamak
  • Captive stainless steel screws
Case material
  • Black painted, zamak
Mounting
  • Wall mounting bracket
Scale
  • Internal, accuracy on reading ± 5 % FS
Performance
Min. pressure range
  • -200 ... 0 mbar
Max. pressure range
  • -25 ... 400 mbar
Repeatability
  • ± 1 % FS
Temperature: Pressure range codes 101 to 153
Ambient temperature
  • -25°C ... +70°C
Storage temperature
  • -40°C ... +40°C ,Code 40
Media temperature
  • -15°C ... +150°C
Wetted parts
Process connection material
  • Stainless steel 1.4404 / AISI 316L
Diaphragm
  • FKM (Viton®)
Electrical data
Electrical connection
  • Via internal terminal block with plastic cable gland for Ø 7 to 10.5 mm
Ground connection
  • Via internal terminal block
Adjustment
  • 2 external adjustment screws on top of the case for set point and deadband
Approval / Conformities
CE conformity
  • Low Voltage Directive 2014/35/UE

Downloads
Data sheet
Operating Manual

Drawings