Technical data
Housing
Protection rating (EN60529)
  • IP66
Cover
  • Blue painted, zamak
  • Captive stainless steel screws
Case material
  • Black painted, zamak
Mounting
  • Wall mounting bracket
Scale
  • Internal, accuracy on reading ± 5 % FS
Process
Process connection
  • G1/4" female, only for codes 161,162,163
  • G1/2"
  • 1/4" NPT female
  • 1/2" NPT
Process connection material
  • Stainless steel 1.4404 / AISI 316L
Temperature
Ambient temperature
  • -25°C ... +55°C
Storage temperature
  • -40°C ... +70°C
Media temperature
  • -15°C ... +150°C
Wetted parts
Flange
  • Stainless steel 1.4404 / AISI 316L
Diaphragm
  • FKM (Viton)
Sensing / Input
Min. measuring range
  • 10 ... 200 mbar
Max. measuring range
  • 10 ... 2000 mbar
Performance
Repeatability
  • ± 1 % FS
Adjustment
  • 2 external adjustment screws on top of the case for set point and deadband
  • The adjustment is not influenced by changes of the static pressure
Electrical data
Ground connection
  • Via internal terminal block
Electrical connection
  • Via internal terminal block with plastic cable gland for Ø 7 to 10.5 mm
Approval / Conformities
CE conformity
  • Low Voltage Directive 2014/35/UE

Downloads
Data sheet
Operating Manual

Drawings
Drawings

Pressure range codes:156 - 157 - 158

(png | 106 KB)

Pressure range codes: 161 - 162 - 163

(png | 70 KB)

To the top